GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces

GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces

Regular price €25,40
Regular price €25,40 Sale price €25,40
Sale Sold out
Taxes included. Shipping calculated at checkout.

GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces they measure the beta-hydroxybutyrate in the blood with the instrument GlucoMen areo 2K: 0.8 microliters, response in 8 seconds, interval 0.1-8.0 mmol/L. The ketone in the blood rises before that in the urine and is useful in case of persistent high blood sugar. Only from fingertip, in single blisters of aluminium.

NET WEIGHT OF THE PRODUCT

10ct

EAN

938766565

MINSAN

938766565

View full details

GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces I'm the sensors for the measurement of ketonemia with the tool GlucoMen areo 2K, the same one that reads blood sugar. The package contains some 10.

What they measure is the beta-hydroxybutyrate, in acronym BOHB: it is the most abundant ketone body in the blood and the one that rises first. Measuring it in the blood is different from looking for it in the urine, where it appears later and already partially disposed of: it is the useful measurement in case of persistent high blood sugar, of intercurrent illness or malfunction of the microinfusor, i.e. in situations in which ketones rise.

Chemistry is a three-piece enzymatic reaction: the D-3-hydroxybutyrate dehydrogenase, the enzyme that recognizes the ketone; the coenzyme NAD+, which collects the electrons of the reaction; and the redox mediator, phenanthroline-dione, which brings them to the electrode. The sensor is recognized by its color light purple, against the white of that of blood sugar.

The measurements: 0.8 microliters of blood, response in 8 seconds, interval from 0.1 to 8.0 mmol/L. The automatic compensation for hematocrit works between 20 and 60%. Coding is not required.

One rule distinguishes these sensors from blood glucose sensors: no alternative sites. The sample must come from fingertip, with fresh capillary blood, because the ketone in the peripheral blood of the palm and forearm does not follow the circulating one quickly enough.

Each sensor is individually packaged in aluminum blister, which is preserved between 4 and 30 degrees without freezing or refrigerating. Validity is 18 months from the date of manufacture.


INDICATIONS

Why use GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces? What is it for?

In vitro diagnostic medical device. Sensors for self-monitoring of ketonemia with the GlucoMen areo 2K instrument, for the quantitative determination of beta-hydroxybutyrate in fresh capillary whole blood.

The system is designed for home monitoring and self-monitoring of blood glucose and beta-ketone levels and can also be used in a hospital environment by medical personnel. It is not intended for use in the diagnosis or screening of diabetic ketoacidosis nor for use in newborns.


HOW TO USE

How do I use GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces?

1. Insert a new GlucoMen areo Beta-Ketone Sensor (light purple) into the sensor opening. The drop symbol will begin to flash on the display and the "Keth" ketone symbol will appear in the bottom left. If nothing appears on the display, remove the sensor, insert it back into the opening and wait for the drop symbol to start flashing.
2. Keep the tip of the sensor in contact with the drop of blood until the control glass fills. You will hear a beep (if enabled) and the display will show a countdown.
3. Read the test results. An audible signal will announce the appearance of the test result on the screen with the ketone symbol "Keth". The symbol will flash until the instrument is turned off.
4. To remove the sensor, press the eject button. The instrument will turn off.
Do not use GlucoMen areo Beta-Ketone Sensors to test samples from alternative sites: use only fresh capillary blood from fingertips.


WARNINGS

What are the warnings of GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces?

GlucoMen areo Beta-Ketone Sensors are to be used exclusively for in vitro diagnostic use (for external use only).
Results may be incorrect if the patient is dehydrated, severely hypertensive, in shock, or in a hyperosmolar state.
Do not test patients in critical health conditions.
If the results of the blood ketone test are not compatible with the patient's perceived state of health despite having followed all the instructions indicated in the user manual of the GlucoMen areo 2K instrument, contact your doctor or healthcare professional.
Never make significant changes to your diabetes control plan without first talking to your doctor.
Keep the instrument, sensors and other system components out of the reach of children. Small parts may pose a choking hazard.
Handle sensors with clean, dry hands.
Dispose of used lancets (needles) and sensors in accordance with local regulations.
Handling blood can be dangerous; Use extreme caution when handling blood, sensors, lancets (needles), and the meter.


CONSERVATION

How is GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces stored?

Store the aluminum blister of the sensors at a temperature of 4-30°C; do not freeze or refrigerate.
Avoid exposure to humidity, heat and direct sunlight. Do not use sensors beyond their expiration date as it may cause incorrect results.
Check the expiry date shown on the aluminum blister.
GlucoMen areo Beta-Ketone Sensor strips are individually packaged in aluminum blisters, with a validity of 18 months from the date of manufacture.


FORMAT

What is the format of GlucoMen Areo Beta-Ketone Sensor Ketonemia 10 Pieces?

Pack of 10 pieces.